Electrostatic Survey

Electrostatic discharges pose a significant ignition hazard when used with flammable substances (gas, vapour & dust) and can lead to fires and explosion. Static discharges can also pose an occupational personnel hazard, lead to electronic component failure and manufacturing product problems.

Mitigate the possible effects of an explosion and fire hazard in your workplace by eliminating the ignition hazard posed by static discharges. By carrying out a thorough inspection of your plant and measuring electrostatic surface voltage. We can assist you to identify the sources of static generation and potential deficiencies or lack of controls that may lead to static generation.

Contact the Consultancy Team Today

DUBLIN OFFICE

+353 1 517 5270

CORK OFFICE

+353 818 315 415

We define electrostatic discharges as a generic term for sparks. All electrostatic sparks in air occur because the high potential (voltage) gradients across a charged surface is sufficiently high to ionise the air in its vicinity. This leads to a conducting path through the air across which the charge (spark) causing the potential gradient can transfer. Charge accumulation occurs when the rate of charge generation exceeds the rate of charge dissipation to earth. The hazard of charge accumulation usually increases with area volume.

There are environment conditions that are required for static electricity to become a source of Ignition. The rate of charge generation must exceed the rate of charge dissipation. The effective energy must exceed the minimum ignition energy of the flammable atmosphere, a static discharge must coincide with a flammable atmosphere and a locally ignited flame must propagate in to the surrounding flammable atmosphere.

We also distinguish between three types of electrostatic discharges. There are spark discharges which occur between two ungrounded and charged conductors with a minimum Ignition energy (MIE) ~ 100 mJ. There is also brush discharges which occur between insulating material and a conductor or even between two insulating materials with a MIE < 3 – 4 mJ. Finally there is a propagating brush discharge which occurs between two insulators. The energy dissipated can be very high (MIE >1000 mJ) and it will ignite most flammable atmospheres.
At each test location of your assessment a calibrated handheld electrostatic voltmeter should measure and record the polarity of static charge (positive or negative), electrostatic surface voltage, maximum and minimum volts, ambient temperature and relative humidity.

After completing your static survey assessment we will be able to effectively manage your static generation risk by:

  • Assessing your existing static control measures (engineering & organisational)
  • Reviewing the properties of the processes which may generate static
  • Measuring potential static generation voltages and calculating hypothetical MIE’s
  • Determining additional basis of safety that need to be implemented
  • Implementing the critical recommendations and actions required to prevent static generation in your workplace

Occupli Consultancy is a leading provider of Electro Static Survey services to clients for many years. At Occupli one of our consultancy aims is to support both industry and our clients in eliminating the ignition hazard posed by static discharges and therefore eliminating and mitigating the possible effects of the explosion and fire hazard in the workplace. We perform Static Survey Assessments for defined areas and activities within the plant where static may pose an explosion, occupational personnel hazard, lead to electronic component failure and manufacturing product problems.

If you need help, assistance or interested in finding out more, please contact our Consultants; Gary Horgan at garyhorgan@occupli.com or email info@occupli.com